HOW
TO: run a delay ramp
-
stop current Run using Calorimeter
Crates
-
ask to stop run and take Calorimeter Crates out
of combined cofiguration
-
set T&C mode
-
open T&C
GUI: /online/config/cal/tanc/TCmon.py
-
set timing for the baseline sampling:
-
click on Global
BLS Mode
-
select x1
- 2 ticks
=> baseline is sampled at -5BC instead
of the nominal -3BC
=> gain path is fixed to x1: this should be used if the pulse is sufficiently
high (DAC > 10000) else use x8 - 2 ticks
-
set ADC Mode
-
click on Global
ADC Mode
-
select Unsup
=> reads out
all cells without Pedestal subtraction or 0-suppression
-
set T&C Mode
-
click on Global
T&C set
-
select x889
-
set read-out timing w.r.t. puls
start
-
click on T&C
for
crate NW 02 0x42
-
enter choosen value in TICK
field
=>
ramps with different values should be taken in order to fix this parameter
take
a ramp with 0 (normal), 2 (2 ticks early), 4 (2 ticks late)
-
verify T&C setting
-
open Calorimeter
Power Supply Montiroting GUI: /online/config/cal/supplies_all.py
-
go toMode
page
-
T&C Mode
should
be 0x889
-
Diag
should
not be 0 for card 2 if non-0 value was given in the Tick-field
-
ADC/BLS Mode
should be 0x8a01 if x1 - 2 ticks or 0x8b01 if x8 - 2ticks
-
set initial Pulser configuration
-
open Pulser
Control GUI: /online/config/cal/pulser.py
-
shutdown all pulsers
-
select all pulsers and click
Shutdown
-
initialize
pulser setting in the GUI
-
select all pulsers you would
like to use
typically all pulsers except ICD (number 12)
using gain
1: DAC=20000
using gain 8: DAC=5000
set: Enable All
! click twice on the enable all buttons after
a shutdown, all enables must be red
set: Cmd All
! click twice on the enable all buttons after
a shutdown, all enables must be red
set: Delay All = 0
! type return, such that the value in the Delay All field is seen in the
6 individual delay fields
-
Download!
all values to pulsers
-
check Pulser settings
-
open Calorimeter
Power Supply Montiroting GUI: /online/config/cal/supplies_all.py
-
go to
PLS
Mode
page:
-
selected channels for all selected
pulsers should be set to 1
-
selected commands for all selected
pulsers should be set to 1
-
DAC values for selected pulsers should
be set to choosen value
-
DELAY values for selected pulsers should
be set to choosen initial value
-
all not selected pulsers should have
DAC value=0, DELAY value=0
-
all not selected channels or commands
should =0
-
start Delay-ramp in the PIB
! in request-field
66 should appear
-
enter ramp parameters
put: 50 (max
255)
put: 5 (min 1, max 255)
put: 50
=> ramp between 0 and 250 with 50 Steps of a delay of 5 units and 50 events
per step
-
Download!
ramp
request to PIB
=> a ramp-status window should pop up
-
start a Pulser run
-
open a Taker-Window, or ask DAQ
shifter
select cal-pulsar-test-1.1.xtm
-
start new run
=>
events should start to be counted in the ramp-status window
=>
when a new step of the ramp occurs the delay values in the supply-all GUI
change
-
stop run, when all events are collected
-
write the run-number carefully to
the logbook! and send it to to bassler@in2p3.fr