RUN: 152186 QUALITY: BAD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 1513 NUMBER OF "ZERO_BIAS" EVENTS: 1513 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 17.32% of noisy events in total: 0.00% of "ring of fire", 17.32% of "coherent noise", 0.00% of "missing crates" ZERO_BIAS: 17.32% of noisy events: 0.00% of "ring of fire", 17.32% of "coherent noise", 0.00% of "missing crates" --------------------------------------------------------------- 1 "bad" towers. These towers are: (ieta,iphi): (30, 63) CRATE/ADC/BLS/TOWER: 6/1/0/3 TOT:: N bad chs: 4 av cell occup: 0.01 mean E: 1.72 sigma: 6.64 EM:: N bad chs: 1 av cell occup: 0.01 mean E: 0.59 sigma: 3.10 HAD:: N bad chs: 3 av cell occup: 0.01 mean E: 2.84 sigma: 8.69 --------------------------------------------------------------- 6 "bad" cells These cells are: HOT! (ieta,iphi)=(17,32) Layer EM3_b (4) CRATE/ADC/BLS/TOWER/DEPTH = 4/0/2/0/2 E/event: -1.13 RMS: 0.03 occupancy: 1.00 (ieta,iphi)=(30,63) Layer EM4 (7) CRATE/ADC/BLS/TOWER/DEPTH = 6/1/0/3/6 E/event: 2.43 RMS: 6.15 occupancy: 0.01 HOT! (ieta,iphi)=(31,62) Layer FH1 (11) CRATE/ADC/BLS/TOWER/DEPTH = 6/2/5/0/7 E/event: -1.91 RMS: 0.82 occupancy: 0.95 (ieta,iphi)=(30,63) Layer FH3 (13) CRATE/ADC/BLS/TOWER/DEPTH = 6/1/0/3/9 E/event: 1.99 RMS: 4.70 occupancy: 0.01 (ieta,iphi)=(30,63) Layer FH4 (14) CRATE/ADC/BLS/TOWER/DEPTH = 6/1/0/3/10 E/event: 2.11 RMS: 4.72 occupancy: 0.01 (ieta,iphi)=(30,63) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 6/1/0/3/11 E/event: 7.80 RMS: 18.46 occupancy: 0.01 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75