RUN: 155601 QUALITY: BAD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 1501 NUMBER OF "ZERO_BIAS" EVENTS: 1501 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- 39 empty towers (Too many empty tower will print only first 16.) (ieta,iphi): (-23, 10) CRATE/ADC/BLS/TOWER: 10/6/5/1 (ieta,iphi): (-24, 9) CRATE/ADC/BLS/TOWER: 10/6/5/2 (ieta,iphi): (-24, 10) CRATE/ADC/BLS/TOWER: 10/6/5/3 (ieta,iphi): (-25, 10) CRATE/ADC/BLS/TOWER: 10/6/6/1 (ieta,iphi): (-26, 10) CRATE/ADC/BLS/TOWER: 10/6/6/3 (ieta,iphi): (-27, 10) CRATE/ADC/BLS/TOWER: 10/6/7/1 (ieta,iphi): (-28, 10) CRATE/ADC/BLS/TOWER: 10/6/7/3 (ieta,iphi): (-29, 9) CRATE/ADC/BLS/TOWER: 10/7/0/0 (ieta,iphi): (-29, 10) CRATE/ADC/BLS/TOWER: 10/7/0/1 (ieta,iphi): (-30, 10) CRATE/ADC/BLS/TOWER: 10/7/0/3 (ieta,iphi): (-31, 10) CRATE/ADC/BLS/TOWER: 10/7/1/1 (ieta,iphi): (-32, 9) CRATE/ADC/BLS/TOWER: 10/7/1/2 (ieta,iphi): (-32, 10) CRATE/ADC/BLS/TOWER: 10/7/1/3 (ieta,iphi): (-33, 9) CRATE/ADC/BLS/TOWER: 10/7/2/0 (ieta,iphi): (-34, 9) CRATE/ADC/BLS/TOWER: 10/7/2/1 (ieta,iphi): (-35, 9) CRATE/ADC/BLS/TOWER: 10/7/2/2 --------------------------------------------------------------- 8.26% of noisy events in total: 0.00% of "ring of fire", 8.26% of "coherent noise", 0.00% of "missing crates" ZERO_BIAS: 8.26% of noisy events: 0.00% of "ring of fire", 8.26% of "coherent noise", 0.00% of "missing crates" --------------------------------------------------------------- 1 "bad" cells These cells are: HOT! (ieta,iphi)=(11,26) Layer EM3_d (6) CRATE/ADC/BLS/TOWER/DEPTH = 3/8/7/0/4 E/event: -1.41 RMS: 0.31 occupancy: 0.82 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75