RUN: 158527 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 366 NUMBER OF "ZERO_BIAS" EVENTS: 366 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 3.83% of noisy events in total: 0.00% of "ring of fire", 3.83% of "coherent noise", 0.00% of "missing crates" ZERO_BIAS: 3.83% of noisy events: 0.00% of "ring of fire", 3.83% of "coherent noise", 0.00% of "missing crates" --------------------------------------------------------------- 2 "bad" towers. These towers are: (ieta,iphi): (21, 32) CRATE/ADC/BLS/TOWER: 4/0/4/0 TOT:: N bad chs: 0 av cell occup: 0.45 mean E: 0.85 sigma: 0.55 EM:: N bad chs: 0 av cell occup: 0.16 mean E: 0.72 sigma: 0.35 HAD:: N bad chs: 0 av cell occup: 0.86 mean E: 0.89 sigma: 0.59 (ieta,iphi): (30, 10) CRATE/ADC/BLS/TOWER: 7/5/4/2 TOT:: N bad chs: 2 av cell occup: 0.17 mean E: -1.43 sigma: 0.64 EM:: N bad chs: 2 av cell occup: 0.38 mean E: -1.49 sigma: 0.57 HAD:: N bad chs: 0 av cell occup: 0.01 mean E: 0.10 sigma: 0.29 --------------------------------------------------------------- 4 "bad" cells These cells are: HOT! (ieta,iphi)=(30,10) Layer EM1 (1) CRATE/ADC/BLS/TOWER/DEPTH = 7/5/4/2/0 E/event: -1.83 RMS: 0.33 occupancy: 0.49 HOT! (ieta,iphi)=(30,10) Layer EM3_a (3) CRATE/ADC/BLS/TOWER/DEPTH = 7/5/4/2/2 E/event: -1.83 RMS: 0.39 occupancy: 0.50 (ieta,iphi)=(-23,16) Layer EM4 (7) CRATE/ADC/BLS/TOWER/DEPTH = 10/11/1/1/6 E/event: 1.91 RMS: 5.98 occupancy: 0.03 (ieta,iphi)=(-37,57) Layer FH4 (14) CRATE/ADC/BLS/TOWER/DEPTH = 11/7/3/0/10 E/event: 1.50 RMS: 6.10 occupancy: 0.06 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75