RUN: 158821 QUALITY: GOOD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 825 NUMBER OF "ZERO_BIAS" EVENTS: 825 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 4.97% of noisy events in total: 0.00% of "ring of fire", 4.97% of "coherent noise", 0.00% of "missing crates" ZERO_BIAS: 4.97% of noisy events: 0.00% of "ring of fire", 4.97% of "coherent noise", 0.00% of "missing crates" --------------------------------------------------------------- 7 "bad" cells These cells are: (ieta,iphi)=(27,23) Layer EM3_a (3) CRATE/ADC/BLS/TOWER/DEPTH = 4/6/7/1/2 E/event: 1.92 RMS: 12.53 occupancy: 0.06 HOT! (ieta,iphi)=(-25,54) Layer EM3_b (4) CRATE/ADC/BLS/TOWER/DEPTH = 11/3/6/1/5 E/event: -1.71 RMS: 0.05 occupancy: 1.00 (ieta,iphi)=(15,25) Layer FH1 (11) CRATE/ADC/BLS/TOWER/DEPTH = 4/4/5/1/7 E/event: 1.53 RMS: 3.77 occupancy: 0.02 (ieta,iphi)=(20,13) Layer FH2 (12) CRATE/ADC/BLS/TOWER/DEPTH = 7/1/7/3/8 E/event: 1.64 RMS: 3.34 occupancy: 0.01 (ieta,iphi)=(20,14) Layer FH2 (12) CRATE/ADC/BLS/TOWER/DEPTH = 7/1/7/2/8 E/event: 1.70 RMS: 4.10 occupancy: 0.01 (ieta,iphi)=(30,63) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 6/1/0/3/11 E/event: 3.50 RMS: 12.18 occupancy: 0.02 (ieta,iphi)=(-12,32) Layer CH3 (17) CRATE/ADC/BLS/TOWER/DEPTH = 2/5/7/3/8 E/event: 6.19 RMS: 2.69 occupancy: 0.03 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75