RUN: 160423 QUALITY: GOOD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 1596 NUMBER OF "ZERO_BIAS" EVENTS: 1596 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 6.83% of noisy events in total: 0.00% of "ring of fire", 6.77% of "coherent noise", 0.06% of "missing crates" ZERO_BIAS: 6.83% of noisy events: 0.00% of "ring of fire", 6.77% of "coherent noise", 0.06% of "missing crates" --------------------------------------------------------------- 9 "bad" cells These cells are: (ieta,iphi)=(-14,6) Layer EM3_a (3) CRATE/ADC/BLS/TOWER/DEPTH = 10/3/0/3/4 E/event: 1.93 RMS: 6.12 occupancy: 0.01 (ieta,iphi)=(-22,8) Layer EM3_b (4) CRATE/ADC/BLS/TOWER/DEPTH = 10/5/0/3/5 E/event: 2.06 RMS: 5.77 occupancy: 0.01 (ieta,iphi)=(20,14) Layer EM3_b (4) CRATE/ADC/BLS/TOWER/DEPTH = 7/1/7/2/2 E/event: 1.59 RMS: 4.94 occupancy: 0.01 (ieta,iphi)=(23,31) Layer EM3_c (5) CRATE/ADC/BLS/TOWER/DEPTH = 4/0/5/1/5 E/event: 2.41 RMS: 9.11 occupancy: 0.01 (ieta,iphi)=(9,6) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 8/4/2/0/9 E/event: 2.55 RMS: 0.22 occupancy: 0.01 (ieta,iphi)=(22,4) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 7/9/4/2/11 E/event: -2.09 RMS: 1.03 occupancy: 0.01 (ieta,iphi)=(22,54) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 6/8/0/2/11 E/event: -2.30 RMS: 0.13 occupancy: 0.01 (ieta,iphi)=(-11,30) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 2/5/1/1/9 E/event: 2.88 RMS: 0.35 occupancy: 0.03 (ieta,iphi)=(13,20) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 4/9/0/0/10 E/event: 2.89 RMS: 0.15 occupancy: 0.05 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75