RUN: 161873 QUALITY: BAD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 440 NUMBER OF "ZERO_BIAS" EVENTS: 440 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- 2304 empty towers (Too many empty tower will print only first 16.) (ieta,iphi): (-13, 33) CRATE/ADC/BLS/TOWER: 0/0/0/0 (ieta,iphi): (-13, 34) CRATE/ADC/BLS/TOWER: 0/0/0/1 (ieta,iphi): (-14, 33) CRATE/ADC/BLS/TOWER: 0/0/0/2 (ieta,iphi): (-14, 34) CRATE/ADC/BLS/TOWER: 0/0/0/3 (ieta,iphi): (-15, 33) CRATE/ADC/BLS/TOWER: 0/0/1/0 (ieta,iphi): (-15, 34) CRATE/ADC/BLS/TOWER: 0/0/1/1 (ieta,iphi): (-16, 33) CRATE/ADC/BLS/TOWER: 0/0/1/2 (ieta,iphi): (-16, 34) CRATE/ADC/BLS/TOWER: 0/0/1/3 (ieta,iphi): (-17, 33) CRATE/ADC/BLS/TOWER: 0/0/2/0 (ieta,iphi): (-17, 34) CRATE/ADC/BLS/TOWER: 0/0/2/1 (ieta,iphi): (-18, 33) CRATE/ADC/BLS/TOWER: 0/0/2/2 (ieta,iphi): (-18, 34) CRATE/ADC/BLS/TOWER: 0/0/2/3 (ieta,iphi): (-19, 33) CRATE/ADC/BLS/TOWER: 0/0/3/0 (ieta,iphi): (-19, 34) CRATE/ADC/BLS/TOWER: 0/0/3/1 (ieta,iphi): (-20, 33) CRATE/ADC/BLS/TOWER: 0/0/3/2 (ieta,iphi): (-20, 34) CRATE/ADC/BLS/TOWER: 0/0/3/3 --------------------------------------------------------------- 100.00% of noisy events in total: 0.00% of "ring of fire", 0.68% of "coherent noise", 100.00% of "missing crates" ZERO_BIAS: 100.00% of noisy events: 0.00% of "ring of fire", 0.68% of "coherent noise", 100.00% of "missing crates" --------------------------------------------------------------- 1 "bad" cells These cells are: (ieta,iphi)=(11,54) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 8/10/3/0/8 E/event: 12.34 RMS: 18.95 occupancy: 0.11 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75