RUN: 165600 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 3181 NUMBER OF "ZERO_BIAS" EVENTS: 3181 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 1.45% of noisy events in total: 0.00% of "ring of fire", 1.38% of "coherent noise", 0.06% of "missing crates" ZERO_BIAS: 1.45% of noisy events: 0.00% of "ring of fire", 1.38% of "coherent noise", 0.06% of "missing crates" --------------------------------------------------------------- 1 "bad" towers. These towers are: (ieta,iphi): (-14, 38) CRATE/ADC/BLS/TOWER: 0/3/0/3 TOT:: N bad chs: 0 av cell occup: 0.95 mean E: -0.60 sigma: 0.38 EM:: N bad chs: 0 av cell occup: 1.00 mean E: -0.43 sigma: 0.08 HAD:: N bad chs: 0 av cell occup: 0.90 mean E: -0.75 sigma: 0.48 --------------------------------------------------------------- 5 "bad" cells These cells are: (ieta,iphi)=(8,48) Layer ECMG (10) CRATE/ADC/BLS/TOWER/DEPTH = 5/1/3/1/1 E/event: 1.50 RMS: 0.14 occupancy: 0.01 HOT! (ieta,iphi)=(30,23) Layer FH2 (12) CRATE/ADC/BLS/TOWER/DEPTH = 4/7/0/3/8 E/event: 3.61 RMS: 0.35 occupancy: 1.00 HOT! (ieta,iphi)=(-32,37) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 0/4/1/2/11 E/event: -3.37 RMS: 0.18 occupancy: 1.00 (ieta,iphi)=(18,44) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 5/3/2/2/11 E/event: 12.21 RMS: 7.69 occupancy: 0.00 (ieta,iphi)=(-11,30) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 2/5/1/1/9 E/event: 2.52 RMS: 0.36 occupancy: 0.01 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75