RUN: 166482 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 1407 NUMBER OF "ZERO_BIAS" EVENTS: 1407 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 2.20% of noisy events in total: 0.07% of "ring of fire", 1.99% of "coherent noise", 0.14% of "missing crates" ZERO_BIAS: 2.20% of noisy events: 0.07% of "ring of fire", 1.99% of "coherent noise", 0.14% of "missing crates" --------------------------------------------------------------- 1 "bad" towers. These towers are: (ieta,iphi): (33, 3) CRATE/ADC/BLS/TOWER: 7/10/2/0 TOT:: N bad chs: 3 av cell occup: 0.06 mean E: 0.92 sigma: 2.81 EM:: N bad chs: 3 av cell occup: 0.02 mean E: 6.32 sigma: 5.07 HAD:: N bad chs: 0 av cell occup: 0.10 mean E: 0.11 sigma: 0.51 --------------------------------------------------------------- 6 "bad" cells These cells are: (ieta,iphi)=(33,3) Layer EM1 (1) CRATE/ADC/BLS/TOWER/DEPTH = 7/10/2/0/0 E/event: 15.40 RMS: 5.11 occupancy: 0.01 (ieta,iphi)=(33,3) Layer EM2 (2) CRATE/ADC/BLS/TOWER/DEPTH = 7/10/2/0/1 E/event: 5.48 RMS: 2.32 occupancy: 0.03 (ieta,iphi)=(33,3) Layer EM3_a (3) CRATE/ADC/BLS/TOWER/DEPTH = 7/10/2/0/2 E/event: 4.21 RMS: 3.30 occupancy: 0.04 HOT! (ieta,iphi)=(-25,54) Layer EM3_b (4) CRATE/ADC/BLS/TOWER/DEPTH = 11/3/6/1/5 E/event: -1.67 RMS: 0.37 occupancy: 0.94 HOT! (ieta,iphi)=(30,23) Layer FH2 (12) CRATE/ADC/BLS/TOWER/DEPTH = 4/7/0/3/8 E/event: 2.06 RMS: 0.25 occupancy: 1.00 (ieta,iphi)=(22,4) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 7/9/4/2/11 E/event: 3.92 RMS: 4.55 occupancy: 0.05 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75