RUN: 166484 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 5312 NUMBER OF "ZERO_BIAS" EVENTS: 5312 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 1.88% of noisy events in total: 0.00% of "ring of fire", 1.69% of "coherent noise", 0.19% of "missing crates" ZERO_BIAS: 1.88% of noisy events: 0.00% of "ring of fire", 1.69% of "coherent noise", 0.19% of "missing crates" --------------------------------------------------------------- 1 "bad" towers. These towers are: (ieta,iphi): (33, 3) CRATE/ADC/BLS/TOWER: 7/10/2/0 TOT:: N bad chs: 3 av cell occup: 0.05 mean E: 1.16 sigma: 3.10 EM:: N bad chs: 3 av cell occup: 0.02 mean E: 6.21 sigma: 4.86 HAD:: N bad chs: 0 av cell occup: 0.08 mean E: 0.11 sigma: 0.55 --------------------------------------------------------------- 6 "bad" cells These cells are: (ieta,iphi)=(33,3) Layer EM1 (1) CRATE/ADC/BLS/TOWER/DEPTH = 7/10/2/0/0 E/event: 13.15 RMS: 5.89 occupancy: 0.01 (ieta,iphi)=(33,3) Layer EM2 (2) CRATE/ADC/BLS/TOWER/DEPTH = 7/10/2/0/1 E/event: 5.36 RMS: 2.35 occupancy: 0.03 (ieta,iphi)=(33,3) Layer EM3_a (3) CRATE/ADC/BLS/TOWER/DEPTH = 7/10/2/0/2 E/event: 4.24 RMS: 3.24 occupancy: 0.04 HOT! (ieta,iphi)=(-25,54) Layer EM3_b (4) CRATE/ADC/BLS/TOWER/DEPTH = 11/3/6/1/5 E/event: -1.52 RMS: 0.37 occupancy: 0.81 (ieta,iphi)=(22,4) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 7/9/4/2/11 E/event: 2.76 RMS: 5.35 occupancy: 0.05 (ieta,iphi)=(-11,30) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 2/5/1/1/9 E/event: 3.10 RMS: 0.33 occupancy: 0.00 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75