RUN: 170035 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 5276 NUMBER OF "ZERO_BIAS" EVENTS: 5276 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 1.65% of noisy events in total: 0.00% of "ring of fire", 1.42% of "coherent noise", 0.23% of "missing crates" ZERO_BIAS: 1.65% of noisy events: 0.00% of "ring of fire", 1.42% of "coherent noise", 0.23% of "missing crates" --------------------------------------------------------------- 1 "bad" towers. These towers are: (ieta,iphi): (-18, 44) CRATE/ADC/BLS/TOWER: 0/7/6/3 TOT:: N bad chs: 1 av cell occup: 0.12 mean E: 0.90 sigma: 3.24 EM:: N bad chs: 0 av cell occup: 0.01 mean E: -0.01 sigma: 0.23 HAD:: N bad chs: 1 av cell occup: 0.31 mean E: 0.96 sigma: 3.33 --------------------------------------------------------------- 6 "bad" cells These cells are: HOT! (ieta,iphi)=(-11,55) Layer EM4 (7) CRATE/ADC/BLS/TOWER/DEPTH = 9/2/7/0/6 E/event: 1.92 RMS: 2.93 occupancy: 0.56 HOT! (ieta,iphi)=(30,23) Layer FH2 (12) CRATE/ADC/BLS/TOWER/DEPTH = 4/7/0/3/8 E/event: 2.83 RMS: 0.22 occupancy: 1.00 HOT! (ieta,iphi)=(-18,44) Layer FH4 (14) CRATE/ADC/BLS/TOWER/DEPTH = 0/7/6/3/10 E/event: 1.70 RMS: 4.20 occupancy: 0.68 (ieta,iphi)=(9,6) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 8/4/2/0/9 E/event: 2.50 RMS: 0.22 occupancy: 0.00 (ieta,iphi)=(22,54) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 6/8/0/2/11 E/event: -2.27 RMS: 0.07 occupancy: 0.00 (ieta,iphi)=(-11,30) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 2/5/1/1/9 E/event: 3.31 RMS: 0.41 occupancy: 0.02 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75