RUN: 170242 QUALITY: GOOD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 1195 NUMBER OF "ZERO_BIAS" EVENTS: 1195 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 2.68% of noisy events in total: 0.00% of "ring of fire", 2.59% of "coherent noise", 0.08% of "missing crates" ZERO_BIAS: 2.68% of noisy events: 0.00% of "ring of fire", 2.59% of "coherent noise", 0.08% of "missing crates" --------------------------------------------------------------- 4 "bad" cells These cells are: (ieta,iphi)=(8,48) Layer ECMG (10) CRATE/ADC/BLS/TOWER/DEPTH = 5/1/3/1/1 E/event: 1.55 RMS: 0.17 occupancy: 0.01 HOT! (ieta,iphi)=(10,45) Layer ECMG (10) CRATE/ADC/BLS/TOWER/DEPTH = 5/2/7/1/7 E/event: 1.66 RMS: 2.45 occupancy: 0.50 HOT! (ieta,iphi)=(30,23) Layer FH2 (12) CRATE/ADC/BLS/TOWER/DEPTH = 4/7/0/3/8 E/event: 1.90 RMS: 0.12 occupancy: 1.00 (ieta,iphi)=(22,4) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 7/9/4/2/11 E/event: 4.41 RMS: 6.65 occupancy: 0.04 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75