RUN: 176875 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 6860 NUMBER OF "ZERO_BIAS" EVENTS: 6860 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- ALL towers have a signal. --------------------------------------------------------------- 2.55% of noisy events in total: 0.01% of "ring of fire", 2.30% of "coherent noise", 0.23% of "missing crates" ZERO_BIAS: 2.55% of noisy events: 0.01% of "ring of fire", 2.30% of "coherent noise", 0.23% of "missing crates" --------------------------------------------------------------- 1 "bad" towers. These towers are: (ieta,iphi): (14, 6) CRATE/ADC/BLS/TOWER: 7/7/4/2 TOT:: N bad chs: 3 av cell occup: 0.02 mean E: 0.99 sigma: 2.72 EM:: N bad chs: 3 av cell occup: 0.03 mean E: 1.36 sigma: 3.18 HAD:: N bad chs: 0 av cell occup: 0.01 mean E: 0.13 sigma: 0.43 --------------------------------------------------------------- 6 "bad" cells These cells are: (ieta,iphi)=(14,6) Layer EM3_c (5) CRATE/ADC/BLS/TOWER/DEPTH = 7/7/4/2/4 E/event: 1.80 RMS: 3.34 occupancy: 0.03 (ieta,iphi)=(14,6) Layer EM3_d (6) CRATE/ADC/BLS/TOWER/DEPTH = 7/7/4/2/3 E/event: 1.81 RMS: 3.45 occupancy: 0.03 (ieta,iphi)=(14,6) Layer EM4 (7) CRATE/ADC/BLS/TOWER/DEPTH = 7/7/4/2/5 E/event: 2.27 RMS: 4.22 occupancy: 0.03 (ieta,iphi)=(-8,7) Layer ECMG (10) CRATE/ADC/BLS/TOWER/DEPTH = 10/5/7/1/1 E/event: 1.52 RMS: 0.18 occupancy: 0.00 (ieta,iphi)=(-11,30) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 2/5/1/1/9 E/event: 2.70 RMS: 0.30 occupancy: 0.02 (ieta,iphi)=(13,20) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 4/9/0/0/10 E/event: 2.85 RMS: 0.13 occupancy: 0.01 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75