RUN: 179200 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 4650 NUMBER OF "ZERO_BIAS" EVENTS: 4650 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- 5 empty towers These towers are: (ieta,iphi): (-11, 37) CRATE/ADC/BLS/TOWER: 2/8/1/0 (ieta,iphi): (-11, 38) CRATE/ADC/BLS/TOWER: 2/8/1/1 (ieta,iphi): (-12, 37) CRATE/ADC/BLS/TOWER: 2/8/1/2 (ieta,iphi): (-12, 38) CRATE/ADC/BLS/TOWER: 2/8/1/3 (ieta,iphi): (1, 7) CRATE/ADC/BLS/TOWER: 8/3/0/1 --------------------------------------------------------------- 2.56% of noisy events in total: 0.02% of "ring of fire", 2.30% of "coherent noise", 0.24% of "missing crates" ZERO_BIAS: 2.56% of noisy events: 0.02% of "ring of fire", 2.30% of "coherent noise", 0.24% of "missing crates" --------------------------------------------------------------- 6 "bad" cells These cells are: HOT! (ieta,iphi)=(12,59) Layer CCMG (8) CRATE/ADC/BLS/TOWER/DEPTH = 6/4/3/1/10 E/event: 2.09 RMS: 0.30 occupancy: 0.89 (ieta,iphi)=(8,48) Layer ECMG (10) CRATE/ADC/BLS/TOWER/DEPTH = 5/1/3/1/1 E/event: 1.54 RMS: 0.18 occupancy: 0.01 (ieta,iphi)=(9,6) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 8/4/2/0/9 E/event: 2.55 RMS: 0.26 occupancy: 0.00 (ieta,iphi)=(16,20) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 4/9/1/2/11 E/event: 5.45 RMS: 2.59 occupancy: 0.00 (ieta,iphi)=(12,6) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 8/4/3/2/7 E/event: 2.97 RMS: 0.25 occupancy: 0.00 (ieta,iphi)=(13,20) Layer CH2 (16) CRATE/ADC/BLS/TOWER/DEPTH = 4/9/0/0/10 E/event: 2.76 RMS: 0.17 occupancy: 0.05 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75