RUN: 185787 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 13545 NUMBER OF "ZERO_BIAS" EVENTS: 13545 NUMBER OF "UNSUPPRESSED" EVENTS: 0 NUMBER OF "JETS" EVENTS: 0 NUMBER OF "ALL OTHER" EVENTS: 0 --------------------------------------------------------------- 1 empty towers These towers are: (ieta,iphi): (-32, 31) CRATE/ADC/BLS/TOWER: 1/11/5/2 --------------------------------------------------------------- 1.81% of noisy events in total: 0.00% of "ring of fire", 1.59% of "coherent noise", 0.21% of "missing crates" ZERO_BIAS: 1.81% of noisy events: 0.00% of "ring of fire", 1.59% of "coherent noise", 0.21% of "missing crates" --------------------------------------------------------------- 2 "bad" cells These cells are: (ieta,iphi)=(-13,29) Layer ICD (9) CRATE/ADC/BLS/TOWER/DEPTH = 1/10/3/2/10 E/event: 1.95 RMS: 2.32 occupancy: 0.00 (ieta,iphi)=(-12,30) Layer ICD (9) CRATE/ADC/BLS/TOWER/DEPTH = 1/10/3/2/8 E/event: 2.30 RMS: 2.39 occupancy: 0.00 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: OFFLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75