RUN: 193994 QUALITY: REASONABLE CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 49512 NUMBER OF "ZERO_BIAS" EVENTS: 3518 NUMBER OF "UNSUPPRESSED" EVENTS: 1620 NUMBER OF "JETS" EVENTS: 18253 NUMBER OF "ALL OTHER" EVENTS: 26121 --------------------------------------------------------------- 1 empty towers These towers are: (ieta,iphi): (-21, 29) CRATE/ADC/BLS/TOWER: 1/9/4/0 --------------------------------------------------------------- 4.86% of noisy events in total: 0.01% of "ring of fire", 4.77% of "coherent noise", 0.08% of "missing crates" ZERO_BIAS: 6.96% of noisy events: 0.00% of "ring of fire", 6.57% of "coherent noise", 0.40% of "missing crates" JETS: 5.03% of noisy events: 0.01% of "ring of fire", 5.02% of "coherent noise", 0.00% of "missing crates" ALL OTHER: 4.75% of noisy events: 0.02% of "ring of fire", 4.65% of "coherent noise", 0.09% of "missing crates" --------------------------------------------------------------- 1 "bad" cells These cells are: (ieta,iphi)=(-17,63) Layer CH1 (15) CRATE/ADC/BLS/TOWER/DEPTH = 11/10/6/0/11 E/event: -2.00 RMS: 2.30 occupancy: 0.00 --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: ONLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75