RUN: 194077 QUALITY: BAD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 43031 NUMBER OF "ZERO_BIAS" EVENTS: 2169 NUMBER OF "UNSUPPRESSED" EVENTS: 972 NUMBER OF "JETS" EVENTS: 17017 NUMBER OF "ALL OTHER" EVENTS: 22873 --------------------------------------------------------------- 38 empty towers (Too many empty tower will print only first 16.) (ieta,iphi): (13, 16) CRATE/ADC/BLS/TOWER: 7/0/0/0 (ieta,iphi): (13, 15) CRATE/ADC/BLS/TOWER: 7/0/0/1 (ieta,iphi): (35, 15) CRATE/ADC/BLS/TOWER: 7/1/2/2 (ieta,iphi): (36, 15) CRATE/ADC/BLS/TOWER: 7/1/2/3 (ieta,iphi): (13, 14) CRATE/ADC/BLS/TOWER: 7/1/4/0 (ieta,iphi): (13, 13) CRATE/ADC/BLS/TOWER: 7/1/4/1 (ieta,iphi): (15, 14) CRATE/ADC/BLS/TOWER: 7/1/5/0 (ieta,iphi): (29, 13) CRATE/ADC/BLS/TOWER: 7/2/4/1 (ieta,iphi): (36, 13) CRATE/ADC/BLS/TOWER: 7/2/6/3 (ieta,iphi): (13, 12) CRATE/ADC/BLS/TOWER: 7/3/0/0 (ieta,iphi): (13, 11) CRATE/ADC/BLS/TOWER: 7/3/0/1 (ieta,iphi): (24, 11) CRATE/ADC/BLS/TOWER: 7/3/5/3 (ieta,iphi): (36, 11) CRATE/ADC/BLS/TOWER: 7/4/2/3 (ieta,iphi): (13, 10) CRATE/ADC/BLS/TOWER: 7/4/4/0 (ieta,iphi): (13, 9) CRATE/ADC/BLS/TOWER: 7/4/4/1 (ieta,iphi): (32, 9) CRATE/ADC/BLS/TOWER: 7/5/5/3 --------------------------------------------------------------- 3.70% of noisy events in total: 0.00% of "ring of fire", 3.31% of "coherent noise", 0.39% of "missing crates" ZERO_BIAS: 4.06% of noisy events: 0.00% of "ring of fire", 2.81% of "coherent noise", 1.29% of "missing crates" JETS: 4.04% of noisy events: 0.00% of "ring of fire", 3.78% of "coherent noise", 0.25% of "missing crates" ALL OTHER: 3.58% of noisy events: 0.01% of "ring of fire", 3.15% of "coherent noise", 0.42% of "missing crates" --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: ONLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75