RUN: 194483 QUALITY: BAD CRITERIA VERSION: 5 TOTAL NUMBER OF EVENTS: 29356 NUMBER OF "ZERO_BIAS" EVENTS: 1734 NUMBER OF "UNSUPPRESSED" EVENTS: 720 NUMBER OF "JETS" EVENTS: 15647 NUMBER OF "ALL OTHER" EVENTS: 11255 --------------------------------------------------------------- 16 empty towers These towers are: (ieta,iphi): (-21, 52) CRATE/ADC/BLS/TOWER: 11/2/0/1 (ieta,iphi): (-22, 52) CRATE/ADC/BLS/TOWER: 11/2/0/3 (ieta,iphi): (-23, 52) CRATE/ADC/BLS/TOWER: 11/2/1/1 (ieta,iphi): (-24, 52) CRATE/ADC/BLS/TOWER: 11/2/1/3 (ieta,iphi): (-25, 52) CRATE/ADC/BLS/TOWER: 11/2/2/1 (ieta,iphi): (-26, 52) CRATE/ADC/BLS/TOWER: 11/2/2/3 (ieta,iphi): (-27, 52) CRATE/ADC/BLS/TOWER: 11/2/3/1 (ieta,iphi): (-28, 52) CRATE/ADC/BLS/TOWER: 11/2/3/3 (ieta,iphi): (-29, 52) CRATE/ADC/BLS/TOWER: 11/2/4/1 (ieta,iphi): (-30, 52) CRATE/ADC/BLS/TOWER: 11/2/4/3 (ieta,iphi): (-31, 52) CRATE/ADC/BLS/TOWER: 11/2/5/1 (ieta,iphi): (-32, 52) CRATE/ADC/BLS/TOWER: 11/2/5/3 (ieta,iphi): (-34, 51) CRATE/ADC/BLS/TOWER: 11/2/6/1 (ieta,iphi): (-36, 51) CRATE/ADC/BLS/TOWER: 11/2/6/3 (ieta,iphi): (-8, 51) CRATE/ADC/BLS/TOWER: 11/2/7/1 (ieta,iphi): (-9, 51) CRATE/ADC/BLS/TOWER: 11/2/7/3 --------------------------------------------------------------- 4.08% of noisy events in total: 0.00% of "ring of fire", 4.06% of "coherent noise", 0.02% of "missing crates" ZERO_BIAS: 2.77% of noisy events: 0.00% of "ring of fire", 2.48% of "coherent noise", 0.29% of "missing crates" JETS: 6.11% of noisy events: 0.00% of "ring of fire", 6.11% of "coherent noise", 0.00% of "missing crates" ALL OTHER: 1.72% of noisy events: 0.00% of "ring of fire", 1.72% of "coherent noise", 0.00% of "missing crates" --------------------------------------------------------------- --------------------------------------------------------------- ---> The run quality creteria are: ---> VERSION: 5 ---> If percentage of noisy events > 10.00 the run quality is BAD. ---> else if number of cells with mean energy out of limits > 24 the run quality is BAD. ---> else if number of ZERO_BIAS events in the run < 200 the run quality is UNKNOWN. ---> else if number of towers without signal > 8 the run quality is BAD. ---> else if number of towers without signal > 0 the run quality is REASONABLE. ---> else if number of BAD towers > 0 the run quality is REASONABLE. ---> else if percentage of noisy events > 8.00 the run quality is REASONABLE. ---> else the run quality is GOOD. --------------------------------------------------------------- PARAMETERS IN USE ARE: Mode: ONLINE Minimal number of events to generate report file: 200 Minimal number of entries per cell: 10 Minimal occupancy per cell to declare it hot: 0.25 Cell mean energy: -1.00 - 1.50 CH cell mean energy: -2.00 - 2.50 Cell RMS: 0.03 - 4.00 Max average occupancy per cell in tower : 0.30 : if abs(ieta) > 32 : 0.50 Max number of bad channels in tower : 3 Tower max mean energy: -0.75 - 0.75